Carrol Touch Modular Flat Panel Specifications Page 153

  • Download
  • Add to my manuals
  • Print
  • Page
    / 274
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 152
Appendix B - Smart-Frame Protocol II Function Reference CARROLL TOUCH
B-4 Touch System Programmer’s Guide
application or driver software should use the default value for that
specific attribute, if a default is defined.
Command Format
11
Report Description
The Get Configuration Report details the configuration of the touch
system.
Report Format
11 ComponentCount
ComponentType
AttributeCount
AttributeTag AttributeValue
AttributeTag AttributeValue...
ComponentType...FF
ComponentCount
= Number of components in the touch system.
ComponentType
= Type of component:
0 = Unknown. The component exists and has
attributes, but its type could not be determined.
1 = Sensor/frame. This is the touch sensing portion of
the touch system, such as a GW sensor or IR
frame.
2 = Controller. This is the portion of the touch system
that controls one or more touch sensing portions
of the touch system.
3 = Processor. This is the portion of the touch system
that executes the operating firmware.
No ComponentType value is defined for Smart-Frames;
Smart-Frames are treated as the combination of a
sensor/frame and a controller.
AttributeCount
= Number of attribute tag/value pairs in the component.
AttributeTag
= Indicates the meaning of the attribute. Values for
AttributeTag depend upon the value of ComponentType.
Refer to Table B-3 for the possible values.
Page view 152